Resource Type

Journal Article 991

Conference Videos 8

Year

2024 2

2023 72

2022 83

2021 66

2020 70

2019 49

2018 42

2017 42

2016 41

2015 50

2014 45

2013 44

2012 41

2011 36

2010 47

2009 45

2008 38

2007 36

2006 27

2005 26

open ︾

Keywords

numerical simulation 16

model 15

model test 15

mathematical model 14

kinetic model 10

COVID-19 7

calibration 7

uncertainty 7

Deep learning 6

optimization 6

sensitivity analysis 6

constitutive model 5

China 4

Machine learning 4

development model 4

numerical model 4

sustainable development 4

FEM 3

artificial neural network 3

open ︾

Search scope:

排序: Display mode:

Corrigendum to ‘‘A Comparison of SWAT Model Calibration Techniques for Hydrological Modeling in the Ganga Corrigendum

Nikita Shivhare, Prabhat Kumar Singh Dikshit, Shyam Bihari

Engineering 2019, Volume 5, Issue 1,   Pages 181-181 doi: 10.1016/j.eng.2018.11.009

Design and calibration of a new high-definition three-dimensional laparoscopic system

Jia TANG,Li-qiang WANG,Bo YUAN,Hong JIANG,Qi-ming ZHU

Frontiers of Information Technology & Electronic Engineering 2015, Volume 16, Issue 1,   Pages 79-84 doi: 10.1631/FITEE.1400149

Abstract: A modified pinhole camera model is used for camera calibration and a new method of depth measurement

Keywords: Dual optical channels     Three dimensional     Camera calibration     Pinhole model     Depth measurement     Laparoscopic    

Light field imaging: models, calibrations, reconstructions,and applications Review

Hao ZHU, Qing WANG, Jingyi YU

Frontiers of Information Technology & Electronic Engineering 2017, Volume 18, Issue 9,   Pages 1236-1249 doi: 10.1631/FITEE.1601727

Abstract: ., model, calibration, and reconstruction,are reviewed extensively.

Keywords: Light field imaging     Plenoptic function     Imaging model     Calibration     Reconstruction    

Development of a novel hand−eye calibration for intuitive control of minimally invasive surgical robot

Frontiers of Mechanical Engineering 2022, Volume 17, Issue 3, doi: 10.1007/s11465-022-0698-y

Abstract: Obtaining the transformation with respect to the laparoscope and robot slave arm frames using hand−eye calibrationWe proposed a novel two-step modified dual quaternion for hand−eye calibration in this study.The dual quaternion was exploited to solve the hand−eye calibration simultaneously and powered by anThe obtained hand−eye calibration result was applied to the intuitive control by using the hand−eye coordinationResults demonstrate this method can improve the calibration accuracy.

Keywords: minimally invasive surgery     hand−eye calibration     intuitive control     surgical robot     dual quaternion    

3D finite element analysis of composite noise barrier constructed of polyurethane products

Ben DAEE,Hesham El NAGGAR

Frontiers of Structural and Civil Engineering 2017, Volume 11, Issue 1,   Pages 100-110 doi: 10.1007/s11709-016-0364-8

Abstract: This paper presents a numerical investigation on the structural performance of an innovative noise barrier consisting of poly-block, rigid polyurethane foam (RPF) and polyurea. The mechanical characteristics of RPF as well as the flexural resistance of the proposed wall system (poly-wall) were established and presented in another study. The experimental results are used in the current study to develop, calibrate and verify 3D finite element (FE) models of the wall system. The components of the poly-wall including steel rebars, poly-blocks and RPF cores were simulated and then verified using the results of experiments conducted on the wall components. The results of numerical analysis exhibited a satisfactory agreement with the experimental outcomes for the entire wall system. The verified numerical models were then used to conduct a parametric study on the performance of poly-wall models under uniform wind load and gravity load. The findings of the current study confirmed that the structural performance of poly-wall is satisfactory for noise barrier application. Simulation techniques for improvement of the numerical analysis of multi-martial 3D FE models were discussed.

Keywords: 3D finite element     sound wall     rigid polyurethane foam     poly-wall     numerical model     calibration    

Development of an onsite calibration device forrobot manipulators Research Article

Ziwei WAN, Chunlin ZHOU, Haotian ZHANG, Jun WU

Frontiers of Information Technology & Electronic Engineering 2023, Volume 24, Issue 2,   Pages 217-230 doi: 10.1631/FITEE.2200172

Abstract: During the calibration procedure, the robot manipulator first moves automatically to multiple end-effectorThe relative mounting positions are accurately measured and used as prior information to improve calibrationThe results of theoretical analysis indicate that MultiCal reduces calibration accuracy by 10% to 20%The results of a calibration experiment conducted on a Staubli TX90 robot show that MultiCal has only7% to 14% lower calibration accuracy compared to a measuring arm with a laser scanner, and 21% to 30%

Keywords: Calibration device     Kinematic calibration     Onsite calibration     Absolute accuracy    

Remote calibration system for frequency based on in-place benchmark

Xiaobin HONG, Guixiong LIU, Zhuokui WU, Xipeng DU,

Frontiers of Mechanical Engineering 2010, Volume 5, Issue 3,   Pages 316-321 doi: 10.1007/s11465-010-0021-1

Abstract: According to the deficiencies of remote calibration mode based on material object reference, a new modelof a remote calibration system for frequency based on in-place benchmark is introduced, which is madeof a calibration subsystem on the spot and a remote management subsystem.The key technology of some key problems for the remote calibration system is particularly discussed,a phase method, frequency division based on dual high-frequency phase locked loop (PLL), and remote calibration

Keywords: remote calibration     in-place benchmark     frequency comparison     global position system (GPS)    

Ultrasound-guided prostate percutaneous intervention robot system and calibration by informative particle

Frontiers of Mechanical Engineering 2022, Volume 17, Issue 1,   Pages 3-3 doi: 10.1007/s11465-021-0659-x

Abstract: The method identifies parameters in the modified kinematic model stepwise according to parameter discernibilityBy applying the calibration method, a reasonable, reliable forward kinematic model is built, and the

Keywords: ultrasound image guidance     prostate percutaneous intervention     parallel robot     kinematics identification     particle swarm optimization     informative value    

Edge detection of steel plates at high temperature using image measurement

Qiong Zhou, Qi An

Frontiers of Mechanical Engineering 2009, Volume 4, Issue 1,   Pages 77-82 doi: 10.1007/s11465-009-0013-1

Abstract: plate; finally, pixel coordinates of the edge position are transformed to physical coordinates through calibration

Keywords: thermal expansion     image measurement     edge detection     image calibration    

Effective optimization and uncertainty assessment of Xin’ anjiang model parameters

Wang Wenchuan,Cheng Chuntian,Qiu Lin,Yang Binbin

Strategic Study of CAE 2010, Volume 12, Issue 3,   Pages 100-107

Abstract:

While Xin'anjiang model is applied to simulate hydrograph, the "best"  parameter set calibrated may be not unique and uncertain because of model limitationConsidering previously parameter optimization of Xin'anjiang model, there is only a unique "The results of calibration and validation indicate that it is feasible and effective for optimizationand uncertainty assessment of Xin'anjiang model parameters.

Keywords: Xin'anjiang model     calibration parameter     uncertainty assessment     SCEM-UA    

Application of micro-genetic algorithm for calibration of kinetic parameters in HCCI engine combustionmodel

HUANG Haozhong, SU Wanhua

Frontiers in Energy 2008, Volume 2, Issue 1,   Pages 86-92 doi: 10.1007/s11708-008-0003-8

Abstract: effective optimization method, is applied to calibrate to a newly developed reduced chemical kinetic modelSimulation results show that the autoignition predictions of the calibrated model agree better with thoseof the detailed chemical kinetic model (544 species and 2 446 reactions) than the original model overThe results of this study have demonstrated that the mGA is an effective tool to facilitate the calibrationof a large number of kinetic parameters in a reduced kinetic model.

Keywords: homogeneous     different     combustion     autoignition     compression    

New method for computer numerical control machine tool calibration: Relay method

LIU Huanlao, SHI Hanming, LI Bin, ZHOU Huichen

Frontiers of Mechanical Engineering 2007, Volume 2, Issue 3,   Pages 301-304 doi: 10.1007/s11465-007-0053-3

Abstract: Relay measurement method, which uses the kilogram-meter (KGM) measurement system to identify volumetric errors on the planes of computer numerical control (CNC) machine tools, is verified through experimental tests. During the process, all position errors on the entire plane table are measured by the equipment, which is limited to a small field. All errors are obtained first by measuring the error of the basic position near the original point. On the basis of that positional error, the positional errors far away from the original point are measured. Using this analogy, the error information on the positional points on the entire plane can be obtained. The process outlined above is called the relay method. Test results indicate that the accuracy and repeatability are high, and the method can be used to calibrate geometric errors on the plane of CNC machine tools after backlash errors have been well compensated.

Keywords: positional     volumetric     information     process     repeatability    

In-orbit calibration and validation of atmospheric correction microwave radiometer on HY-2A satellite

Wang Zhenzhan,Zhang Dehai,Zhao Jin and Li Yun

Strategic Study of CAE 2013, Volume 15, Issue 7,   Pages 44-52

Abstract: After discussion and analysis on thermal vacuum calibration method of ACMR, microwave transfer functions

Keywords: HY-2A     ACMR     calibration and validation    

A Comparison of SWAT Model Calibration Techniquesfor Hydrological Modeling in the Ganga River Watershed

Nikita Shivhare, Prabhat Kumar Singh Dikshit, Shyam Bihari

Engineering 2018, Volume 4, Issue 5,   Pages 643-652 doi: 10.1016/j.eng.2018.08.012

Abstract: study are: To test the execution and applicability of the SWAT modelrunoff and sediment yield; and to compare and determine the best calibrationThe input data used in the SWAT were the Shuttle Radar Topography Mission (SRTM) digital elevation modelalgorithms for use in calibrating Indian watersheds, as this method requires fewer runs for a computational modelThe calibrated model can be utilized in future to facilitate investigation of the impacts of LULC, climate

Keywords: Remote sensing     Geographic information system     Soil and Water Assessment Tool     Hydrological modeling     SUFI-2     GLUE     ParaSol     Sediment yield    

Design of altimeter sea surface height calibration buoy based on GPS

Chen Chuntao,Yan Longhao,Zhang Xiaoxu,Zhang Qian,Zhai Wanlin,Zhu Jianhua

Strategic Study of CAE 2014, Volume 16, Issue 6,   Pages 109-112

Abstract:

GPS buoy is the important instrument for the calibration of altimeterThe result shows that designed GPS buoy can meet the challenge of altimeter sea surface height calibration

Keywords: Satellite altimeter     calibration     GPS buoy     numerical simulation    

Title Author Date Type Operation

Corrigendum to ‘‘A Comparison of SWAT Model Calibration Techniques for Hydrological Modeling in the Ganga

Nikita Shivhare, Prabhat Kumar Singh Dikshit, Shyam Bihari

Journal Article

Design and calibration of a new high-definition three-dimensional laparoscopic system

Jia TANG,Li-qiang WANG,Bo YUAN,Hong JIANG,Qi-ming ZHU

Journal Article

Light field imaging: models, calibrations, reconstructions,and applications

Hao ZHU, Qing WANG, Jingyi YU

Journal Article

Development of a novel hand−eye calibration for intuitive control of minimally invasive surgical robot

Journal Article

3D finite element analysis of composite noise barrier constructed of polyurethane products

Ben DAEE,Hesham El NAGGAR

Journal Article

Development of an onsite calibration device forrobot manipulators

Ziwei WAN, Chunlin ZHOU, Haotian ZHANG, Jun WU

Journal Article

Remote calibration system for frequency based on in-place benchmark

Xiaobin HONG, Guixiong LIU, Zhuokui WU, Xipeng DU,

Journal Article

Ultrasound-guided prostate percutaneous intervention robot system and calibration by informative particle

Journal Article

Edge detection of steel plates at high temperature using image measurement

Qiong Zhou, Qi An

Journal Article

Effective optimization and uncertainty assessment of Xin’ anjiang model parameters

Wang Wenchuan,Cheng Chuntian,Qiu Lin,Yang Binbin

Journal Article

Application of micro-genetic algorithm for calibration of kinetic parameters in HCCI engine combustionmodel

HUANG Haozhong, SU Wanhua

Journal Article

New method for computer numerical control machine tool calibration: Relay method

LIU Huanlao, SHI Hanming, LI Bin, ZHOU Huichen

Journal Article

In-orbit calibration and validation of atmospheric correction microwave radiometer on HY-2A satellite

Wang Zhenzhan,Zhang Dehai,Zhao Jin and Li Yun

Journal Article

A Comparison of SWAT Model Calibration Techniquesfor Hydrological Modeling in the Ganga River Watershed

Nikita Shivhare, Prabhat Kumar Singh Dikshit, Shyam Bihari

Journal Article

Design of altimeter sea surface height calibration buoy based on GPS

Chen Chuntao,Yan Longhao,Zhang Xiaoxu,Zhang Qian,Zhai Wanlin,Zhu Jianhua

Journal Article